SiPM as miniaturised optical biosensor for DNA-microarray applications

2015

A miniaturized optical biosensor for low-level fluorescence emitted by DNA strands labelled with CY5 is showed. Aim of this work is to demonstrate that a Si-based photodetector, having a low noise and a high sensitivity, can replace traditional detection systems in DNA-microarray applications. The photodetector used is a photomultiplier (SiPM), with 25 pixels. It exhibits a higher sensitivity than commercial optical readers and we experimentally found a detection limit for spotted dried samples of ∼1 nM. We measured the fluorescence signal in different operating conditions (angle of analysis, fluorophores concentrations, solution volumes and support). Once fixed the angle of analysis, for s…

Detection limitAnalytePhotomultiplierMaterials scienceoptical biosensorbusiness.industrySiPMDNA microarrayPhotodetectorLinearityDNA-microarraySignalSettore ING-INF/01 - ElettronicaElectronic Optical and Magnetic MaterialsSilicon photomultiplierOpticslcsh:TA1-2040DNA microarray; Fluorophore detection; Optical Biosensor; SiPMSignal ProcessingElectrical and Electronic Engineeringbusinesslcsh:Engineering (General). Civil engineering (General)Sensitivity (electronics)Fluorophore detectionBiotechnologySensing and Bio-Sensing Research
researchProduct

Clinical measurements analysis of multi-spectral photoplethysmograph biosensors

2014

The developed portable multi-spectral photoplethysmograph (MS-PPG) optical biosensor device, intended for analysis of peripheral blood volume pulsations at different vascular depths, has been clinically verified. Multi-spectral monitoring was performed by means of a four – wavelengths (454 nm, 519 nm, 632 nm and 888 nm) light emitted diodes and photodiode with multi-channel signal output processing. Two such sensors can be operated in parallel and imposed on the patient’s skin. The clinical measurements confirmed ability to detect PPG signals at four wavelengths simultaneously and to record temporal differences in the signal shapes (corresponding to different penetration depths) in normal a…

Materials sciencebusiness.industryMulti spectralOptical biosensorPeripheral bloodPhotodiodelaw.inventionWavelengthlawPhotoplethysmogramOptoelectronicssense organsbusinessBiosensorDiodeBiomedical engineeringBiophotonics: Photonic Solutions for Better Health Care IV
researchProduct

Porous Aluminium Oxide Coating for the Development of Spectroscopic Ellipsometry Based Biosensor: Evaluation of Human Serum Albumin Adsorption

2020

An electrochemically synthesised porous anodic aluminium oxide (pAAO) layer has been analysed by means of spectroscopic ellipsometry. The determined thickness of the formed pAAO layer obtained from spectroscopic ellipsometry measurements and modelling was 322.75 &plusmn

Materials scienceporous aluminium oxide02 engineering and technology010402 general chemistry01 natural sciencesspectroscopic ellipsometryoptical biosensorschemistry.chemical_compoundAdsorptionDesorptionMaterials ChemistrymedicineSurfaces and InterfacesBuffer solution021001 nanoscience & nanotechnologyHuman serum albumin0104 chemical sciencesSurfaces Coatings and FilmsNanoporechemistrylcsh:TA1-2040human serum albuminAluminium oxidespectroscopic ellipsometry ; human serum albumin ; porous aluminium oxide ; optical biosensorslcsh:Engineering (General). Civil engineering (General)0210 nano-technologyBiosensorLayer (electronics)Nuclear chemistrymedicine.drugCoatings
researchProduct

Optical biosensors based on ZnO nanostructures: advantages and perspectives. A review

2016

This review article highlights the application of beneficial physico-chemical properties of ZnO nanostructures for the detection of wide range of biological compounds. As the medical diagnostics require accurate, fast and inexpensive biosensors, the advantages inherent optical methods of detection are considered. The crucial points of the immobilization process, responsible for biosensor performance (biomolecule adsorption, surface properties, surface defects role, surface functionalization etc.) along with the interaction mechanism between biomolecules and ZnO are disclosed. The latest achievements in surface plasmon resonance (SPR), surface enhanced Raman spectroscopy (SERS) and photolumi…

NanostructurePhotoluminescenceMaterials scienceNanotechnology02 engineering and technology010402 general chemistry01 natural sciencesAdsorptionMaterials Chemistry[CHIM]Chemical SciencesElectrical and Electronic EngineeringSurface plasmon resonanceInstrumentationComputingMilieux_MISCELLANEOUSchemistry.chemical_classificationBiomoleculeMetals and AlloysKemiSurface-enhanced Raman spectroscopy021001 nanoscience & nanotechnologyCondensed Matter Physics0104 chemical sciencesSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialschemistryOptical biosensors; ZnO; Nanostructures; Immobilization; Photoluminescence based biosensors; Interaction mechanismChemical SciencesSurface modification0210 nano-technologyBiosensor
researchProduct

Screening contact allergens from cosmetics using an optical biosensor

2006

OPTICAL BIOSENSORCONTACT ALLERGENS[SPI.GPROC] Engineering Sciences [physics]/Chemical and Process EngineeringSKIN SENSITIZATIONNUCLEOPHILIC AMINO ACIDS[SDV.IDA]Life Sciences [q-bio]/Food engineering[SPI.GPROC]Engineering Sciences [physics]/Chemical and Process Engineering[SDV.IDA] Life Sciences [q-bio]/Food engineering
researchProduct

Porous silicon photoluminescence biosensor for rapid and sensitive detection of toxins

2017

A rapid and low cost photoluminescence (PL) immunosensor for the determination of low concentrations of Ochratoxin A(OTA) and Aflatoxine B1 (AfB1) has been developed. This biosensor was based on porous silicon (PSi) fabricated by metal-assisted chemical etching (MACE) and modified by antibodies against OTA/AfB1 (anti-OTA/anti-AfB1). Biofunctionalization method of the PSi surface by anti-OTA/ anti-AfB1 was developed. The changes of the PL intensity after interaction of the immobilized anti-OTA/anti-AfB1with OTA/AfB1 antigens were used as biosensor signal, allowing sensitive and selective detection of OTA/AfB1 antigens in BSA solution. The sensitivity of the reported optical biosensor towards…

Ochratoxin AChromatographyPhotoluminescenceMaterials science010401 analytical chemistrytechnology industry and agricultureAnalytical chemistry02 engineering and technologyOptical biosensor021001 nanoscience & nanotechnologyPorous silicon01 natural sciencesIsotropic etching0104 chemical scienceschemistry.chemical_compoundchemistry0210 nano-technologyBiosensorVolume concentrationOrganic Sensors and Bioelectronics X
researchProduct

Si photomultipliers for bio-sensing applications

2016

In this paper, silicon photomultipliers (SiPM) are proposed as optical detectors for bio sensing. Optical transduction is the most used detection mechanism in many biosensor applications, such as DNA microarray and real-time polymerase chain reaction. The performances of a 25 pixels device used for both applications are studied. The results confirm that the SiPM is more sensitive than the traditionally employed detectors. In fact, it is able to experimentally detect 1 nM and 100 fM of fluorophore concentrations in dried samples and solutions, respectively. We present and discuss in details the detector configuration and its characterization as fluorescence detector for bio sensing.

Optical biosensor systemPhotomultiplierFluorophoreMaterials sciencePixel010308 nuclear & particles physics010401 analytical chemistryDetectorDNA microarrayDNA microarray Optical biosensor system RT PCR Silicon PhotomultipliersNanotechnologySilicon Photomultipliers01 natural sciencesFluorescenceSettore ING-INF/01 - ElettronicaAtomic and Molecular Physics and OpticsFluorescence spectroscopy0104 chemical scienceschemistry.chemical_compoundSilicon photomultiplierchemistry0103 physical sciencesElectrical and Electronic EngineeringBiosensorRT PCR
researchProduct

A Review of Biosensors for Non-Invasive Diabetes Monitoring and Screening in Human Exhaled Breath

2019

Exhaled breath acetone has been identified as a diabetes biomarker for non-invasive diagnosis. Its detection using biosensors features has many advantages over the conventional means. This paper reviews the recent literature on the detection of exhaled breath acetone and acetone vapor of diabetic interest. The biosensors have been classified based on their transduction methods. The performance characteristics of the biosensors have been explored for comparison. The future trends are also highlighted.

mass sensitive sensorsmedicine.medical_specialtyGeneral Computer Sciencemacromolecular substances02 engineering and technology01 natural sciencesDiabetes monitoringmedicineGeneral Materials ScienceBreath acetoneIntensive care medicineoperational temperatureelectrochemical biosensorsfuture trendsmicrowave biosensors optical biosensorsbusiness.industry010401 analytical chemistryNon invasivetechnology industry and agricultureGeneral Engineering021001 nanoscience & nanotechnology0104 chemical sciencesBiomarkerlcsh:Electrical engineering. Electronics. Nuclear engineering0210 nano-technologybusinesslcsh:TK1-9971BiosensorIEEE Access